Ahwaz Electromechanical Technology

Focusing on Instrumentation: Competitive Pricing with Swift Delivery

EJA130EDifferentialPressureTransmitter-AhwazAutomation|ProcessControls|AhwazMeasurementInstruments

YOKOGAWA/Pressure Transmitter/Differential Pressure/

EJA130E Differential Pressure Transmitter

The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa. The EJA130E is a differential pressure transmitter designed to work in a high static pressure enviroment. EJA130E features include: ± 0.055% Accuracy ± 0.1% Stability per 10 years 150 ms Response Time 4,500 psi MWP Exida and TUV SIL 2/3 Certified Local Parameter Setting (LPS) EJA130E Overview Refer to the General Specification sheet located under the 'Downloads' tab for detailed specifications. Measurement Types Primary Variable Differential Pressure (DP) Secondary Variable Static Pressure…

  • Product Details

The EJA-E series of transmitters is Yokogawa’s most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.

The EJA130E is a differential pressure transmitter designed to work in a high static pressure enviroment.

EJA130E features include:

  • ± 0.055% Accuracy
  • ± 0.1% Stability per 10 years
  • 150 ms Response Time
  • 4,500 psi MWP
  • Exida and TUV SIL 2/3 Certified
  • Local Parameter Setting (LPS)

EJA130E Overview

Refer to the General Specification sheet located under the ‘Downloads’ tab for detailed specifications.

Measurement Types
Primary VariableDifferential Pressure (DP)
Secondary VariableStatic Pressure (SP)
Reference Accuracy
Primary Variable±0.055% of DP Span
Secondary Variable±0.5% of SP Span
Long Term Stability (All Normal Operating Conditions)
Primary Variable±0.1% of URL per 10 years
Maximum Pressure Limit (MWP)
All Capsules4,500 psi
Over-pressure Effect
Primary Variable±0.03% of URL
Rangeability
Primary Variable100:1
Burst Pressure
All Capsules19,100 psi (132 MPa)
Specification Conformance
EJX-A Series±3σ