Overview
Plants run better with Yokogawa differential pressure transmitters.
At it’s heart, Yokogawa’s differential pressure transmitter with DPharp digital sensor offers the performance and device intelligence needed to get greater insight into your process.
EJX630A Overview
Refer to the General Specification sheet located under the ‘Downloads’ tab for detailed specifications.
Measurement Types | |
---|---|
Primary Variable | Absolute Pressure |
Reference Accuracy | |
Primary Variable | ±0.04% of Span ±0.025% of Span (/HAC option) |
Stability | |
Primary Variable | ±0.1% of URL per 15 years |
Response Time | |
Primary Variable | 90ms |
Rangeability | |
Primary Variable | A Capsule: 100:1 B, C, or D Capsule: 200:1 |
Burst Pressure (Absolute) | |
A, B, or C Capsule | 7,250 psi (50 MPa) |
D Capsule | 26,390 psi (182 MPa) |
Specification Conformance | |
EJX-A Series | ±3σ |