EJXC80A, EJAC80E
Direct Mounted Diaphragm Seal System consists of gauge pressure or differential pressure transmitter with single direct mount diaphragm seal. Suitable for various kinds of pressure measurement.
Direct Mount Flanged Diaphragm Seal System
- EJXC80A Differential pressure direct mount flanged diaphragm seal system
Measurement Span | Range | ||
---|---|---|---|
M | 1 to 100 kPa | −100 to 100 kPa | |
H | 5 to 500 kPa | −500 to 500 kPa | |
V | Flush type | 0.14 to 14 MPa | −0.5 to 14 MPa |
Extended type | 0.14 to 7 MPa | −0.5 to 7 MPa |
- EJAC80E Differential pressure direct mount flanged diaphragm seal system
Measurement Span | Range | ||
---|---|---|---|
M | 1 to 100 kPa | −100 to 100 kPa | |
H | 5 to 500 kPa | −500 to 500 kPa | |
V | Flush type | 0.14 to 14 MPa | −0.5 to 14 MPa |
Extended type | 0.14 to 7 MPa | −0.5 to 7 MPa |
Item | Specifications |
---|---|
Applicable Products (transmitter) | Differential Pressure Transmitter: EJX110A, EJA110E |
Process connection size |
|
Key Features
- High Accuracy
- Safety as Standard
- 120 msec Response Time
- LPS (Local Parameter Setting)
- Signal Characterizer for the 4 to 20 mA output
Key Features
- High performance, high accuracy and high reliability.
- Fast response: 120 ms