Specifications
Area Classification | ATEX Group II Category 2 Gas and Dust, CUTR for Groups II/III Category 2 Equipment |
Certifications | ATEX, CUTR, PED |
Communication Protocol | 3-15 or 6-30 psi, 0.2 -1.0 or 0.4 -2.0 bar Pneumatic Signal |
Diagnostics | No |
| Pneumatic |
Max Outlet Pressure | 150 psi |
Mounting Type | Actuator Mounted |
Operating Temperature | Standard Temperature, High Temperature |
Position Control | Modulating |
Safety Certification | NIL |
Supply Media | Air, Natural Gas |
Features
- 3710 positioners use field-proven spool valve technology for a simple design that gives accurate, fast-responding operation with high cycle life.
- Case, components, and gasket materials withstand harsh environments.
- With EPDM O-rings and input module diaphragm, 3710 positioners can be used in low temperature applications.
- 3710 positioners with fluorocarbon or EPDM O-rings and an input module diaphragm can be used in applications with special material requirements, as in the food and beverage industry, pharmaceuticals, and tobacco processing.
- Changes in supply pressure and ambient temperature have minimal effect on positioner operation.
- To support diagnostic testing of valve/actuator/positioner packages, connectors, piping, and other hardware can be installed between the 3710 positioner and the actuator.
- Standard, low-profile indicator or optional beacon-style indicator mount easily to the positioner cover.