Specifications
- Output variables
- Mass flow
- Volume flow
- Local display
- Standard user interface with 2-line LCD panel
- Two optical switches for local operation
- Glass or plastic lens options
- Power
- Self-switching AC/DC input, automatically recognizes supply voltage
- 85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum
- 18 to 100 VDC, 6 watts typical, 11 watts maximum
- Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2, and Installation (Overvoltage) Category II, Pollution Degree 2
- Input/output signals
- One active 4–20 mA output
- One active frequencty output
- Frequency output can be configured as a discrete output
- HART
- Bell 202 signal is superimposed on the primary milliamp output
- Mounting options
- Field-mount
- Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor
- Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
- Application types
- Continuous process control
- Two-phase flow/entrained gas
- Meter verification
- SIS Certified
- Hazardous approvals
- Class I, Div. 1
- Class I, Div. 2
- Zone 1
- Zone 2
Features
- Maximize flexibility with integral or remote mounting
- Receive diagnostics for performance under entrained gas and batching from empty applications with MVD digital processing
- Lower wiring costs and install easily and quickly
- Eliminate the need for additional instruments with concentration and net flow measurement
- Rely on custody-transfer approval and certification for SIL2 and SIL3
- Gain real-time and in-process measurement integrity assurance with Smart Meter Verification
- Gain access to additional diagnostics and process information without added wiring costs with WirelessHART
- Simplify flow-meter access with rugged Class I, Division 1 / Zone 1 housing with an optional local operator interface