Specifications
- Output variables:
- Mass & volume flow
Net product content / flow
Temperature:
Density
Concentration:
- Local display
- Standard user interface with 2-line LCD panel
Two optical switches for local operation
Glass or plastic lens options
- Power:
- Self-switching AC/DC input, automatically recognizes supply voltage
85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum
18 to 100 VDC, 6 watts typical, 11 watts maximum
Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2, and Installation (Overvoltage) Category II, Pollution Degree 2
- Input/output signals:
- Not intrinsically safeAnalog output option:
- One active 4–20 mA output
- One active frequencty output
Frequency output can be configured as a discrete output
Configurable I/O option:
- One or two active 4-20 mA outputs
- One or two active/passive frequency outputs
- One or two active/passive discrete outputs
- One discrete input
- Intrinsically safe
- Not intrinsically safeAnalog output option:
- Analog output option:
- One passive 4-20 mA output
- One passive frequency output
- Frequency output can be configured as a discrete output
- Foundation fieldbus (Obsolete)
- optionally non-incendive
- One Foundation fieldbus H1 output
- PROFIBUS-PA (Obsolete)
- One PROFIBUS-PA output
- HART/WirelessHART:
- Bell 202 signal is superimposed on the primary milliamp output
WirelessHART available via THUM adapter
HART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions
- Mounting options:
- Field-mount
- Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor
- Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
- Application types:
- Continuous process control
Custody transfer
Two-phase flow/entrained gas
Meter verification
SIS Certified - Hazardous approvals:
- Class I, Div. 1
Class I, Div. 2
Zone 1
Zone 2
- HART/WirelessHART:
- Bell 202 signal is superimposed on the primary milliamp output
WirelessHART available via THUM adapter
HART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions
- Mounting options:
- Field-mount
•Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor
•Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
- Application types:
- Continuous process control
Custody transfer
Two-phase flow/entrained gas
Meter verification
SIS Certified
- Hazardous approvals:
- Class I, Div. 1
- Class I, Div. 2
Zone 1
Zone 2
Features
- Maximize flexibility with integral or remote mounting
- Receive diagnostics for performance under entrained gas and batching from empty applications with MVD digital processing
- Lower wiring costs and install easily and quickly
- Eliminate the need for additional instruments with concentration and net flow measurement
- Rely on custody-transfer approval and certification for SIL2 and SIL3
- Gain real-time and in-process measurement integrity assurance with Smart Meter Verification
- Gain access to additional diagnostics and process information without added wiring costs with WirelessHART
- Simplify flow-meter access with rugged Class I, Division 1 / Zone 1 housing with an optional local operator interface