Specifications
- Output variables
- Mass & volume flow
- Net product content / flow
- Temperature
- Density
- Concentration
- Local display
- Multi-line LCD panel
- Backlit LCD, 128 × 128 pixel, bit map
- Adjustable contrast
- Non-glare, chemical-resistant acrylic lens
- Large push buttons with tactile feedback
- Software-defined function keys
- Power
- AC option:
- 85 to 265 VAC
- 50/60 Hz, 30 VA
- Complies with European low-voltage directive 2006/95/EC per IEC 61010-1, and Installation (Overvoltage) Category II, Pollution Degree 2DC option:
- 18 to 30 VDC
- 18 watts
typical, 25 watts maximum
- Input/output signals
- TTwo active 4–20 mA
- Three discrete outputs
- One 2-wire frequency output
- One 2-wire frequency input
- Two discrete momentary inputs
- HART/WirelessHART
- Bell 202 signal is superimposed on the primary milliamp output
- Mounting options
- Control-room DIN rail or panel-mount
- Application types
- Batch controller
- Custody transfer
- Two-phase flow/entrained gas
- Meter verification
- Hazardous approvals
- Suitable for non-hazardous areas only
Features
- Decrease your plant’s labor, maintenance and operating costs with transmitter functions and PLC capabilities
- Increase efficiency, accelerate throughput and improve product quality
- Eliminate the need for external tools with full configuration capabilities
- Improve interaction with a large, programmable display and descriptive alarms for easy setup, control and operation
- Maximize uptime and process consistency with MVD technology that speeds response and enables multivariable measurement