Micro Motion HPC015M Coriolis Meter, 1/8 INCH (DN3), stainless steel, 6,991 psi (482 bar) maximum operating pressure

Micro Motion 3500 Controller And Transmitter, Remote Rack/Panel-Mount

  • Product Details

Specifications

Micro Motion HPC015M Coriolis Meter, 1/8 INCH (DN3), stainless steel, 6,991 psi (482 bar) maximum operating pressure
Flow Rate:
                 Up to 504 kg/hr (1110 lb/hr)
Liquid Mass Flow Acccuracy:
                   Up to±0.1% of rate
Liquid Mass Flow Repeatability:
                   Up to±0.05% of rate
Gas Mass Flow Accuracy:
                  ±0.5% of rate
Gas Mass Flow Repeatability:
                  ±0.25% of rate
Liquid Density Accuracy:
                  up to ± 0.001 g/cc at standard conditions
Fluid temperature Range:
                 -46 C to 200 C (-50 – 392 F)
Pressure Range :
                 0-6991 psi (0-482 bar)
Micro Motion 3500 Controller And Transmitter, Remote Rack/Panel-Mount
Output variables
  • Mass & volume flow
  • Net product content / flow
  • Temperature
  • Density
  • Concentration
Local display
Multi-line LCD panel

  • Backlit LCD, 128 × 128 pixel, bit map
  • Adjustable contrast
  • Non-glare, chemical-resistant acrylic lens
  • Large push buttons with tactile feedback
  • Software-defined function keys
Power
AC option:

  • 85 to 265 VAC
  • 50/60 Hz, 30 VA
  • Complies with European low-voltage directive 2006/95/EC per IEC 61010-1, and Installation (Overvoltage) Category II, Pollution Degree 2DC option:
  • 18 to 30 VDC
  • 18 watts

typical, 25 watts maximum

Input/output signals
  • TTwo active 4–20 mA
  • Three discrete outputs
  • One 2-wire frequency output
  • One 2-wire frequency input
  • Two discrete momentary inputs
HART/WirelessHART:
           Bell 202 signal is superimposed on the primary milliamp output
           Mounting options
           Control-room DIN rail or panel-mount
Application types:
  • Batch controller
  • Custody transfer
  • Two-phase flow/entrained gas
  • Meter verification
Hazardous approvals:
         Suitable for non-hazardous areas only

Features

Micro Motion HPC015M Coriolis Meter, 1/8 INCH (DN3), stainless steel, 6,991 psi (482 bar) maximum operating pressure
  • Realize superior performance in high-pressure applications
  • Use one device for reliable and repeatable mass flow, volume flow, density, concentration and temperature measurement
  • Get the best real-world Coriolis performance at operating pressures up to 6991 psi (0-482 bar)
  • Minimize maintenance and boost long-term reliability with no moving parts to wear or replace
  • Maximize uptime using Smart Meter Verification to check system integrity without need to pull meter out of service
  • Accommodate any installation requirement with available two-wire, direct-connect (no transmitter needed), stainless steel and 5700 transmitters
  • Dramatically reduce operating expenses for chemical injection and hydrogen dispensers.
Micro Motion 3500 Controller And Transmitter, Remote Rack/Panel-Mount
  • Decrease your plant’s labor, maintenance and operating costs with transmitter functions and PLC capabilities
  • Increase efficiency, accelerate throughput and improve product quality
  • Eliminate the need for external tools with full configuration capabilities
  • Improve interaction with a large, programmable display and descriptive alarms for easy setup, control and operation
  • Maximize uptime and process consistency with MVD technology that speeds response and enables multivariable measurement