Specifications
Micro Motion HPC015P Coriolis Meter, 1/8 INCH (DN3), stainless steel, 15,375 psi (1060 bar) maximum operating pressure
- Flow Rate:
- Up to 504 kg/hr (1110 lb/hr)
- Liquid Mass Flow Acccuracy:
- Up to±0.1% of rate
- Liquid Mass Flow Repeatability:
- Up to±0.05% of rate
- Gas Mass Flow Accuracy:
- ±0.5% of rate
- Gas Mass Flow Repeatability:
- ±0.25% of rate
- Liquid Density Accuracy:
- up to ± 0.001 g/cc at standard conditions
- Fluid temperature Range:
- -46 C to 200 C (-50 – 392 F)
- Pressure Range:
- 0-15,374 psi (0-1,060 bar)
Micro Motion 2400S Compact, Integral-Mount Transmitter
- Output variables:
- Mass & volume flow
Net product content / flow
Temperature
Density
Concentration - Local display:
- Standard user interface with 2-line LCD panel
Two clips for HART/Bell 202 connections (requires removing transmitter housing cover)
Two membrane pushbuttons for local operation (requires removing transmitter housing cover)
Glass or plastic lens options
- Power:
- Self-switching AC/DC input, automatically recognizes supply voltage
85–265 VAC, 50/60 Hz, 4 watts typical, 7 watts maximum
18–100 VDC, 4 watts typical, 7 watts maximum
Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) and Installation (Overvoltage) Category II, Pollution Degree 2
- Input/output signals (analog output option):
- Channel A:
One active 4–20 mA output
Not intrinsically safeChannel B (configurable), one of:
One active or passive frequency output
One active or passive discrete output
One active or passive discrete input
- Input/output signals (PROFIBUS-DP option):
- Digital 2-way PROFIBUS-DP signal
- Input/output signals (DeviceNet option):
- Digital 2-way DeviceNet signal (Now Obsolete)
- HART:
- Bell 202 signal is superimposed on the primary milliamp output
HART communication is not available on PROFIBUS-DP and DeviceNet transmitter versions
- Mounting options:
- Field mount, integral with sensor
- Application types:
- Continuous process control
Two-phase flow/entrained gas
Meter verification
- Hazardous approvals:
- C1D2
Zone 2 Features
Micro Motion HPC015P Coriolis Meter, 1/8 INCH (DN3), stainless steel, 15,375 psi (1060 bar) maximum operating pressure- Realize superior performance in high-pressure applications
- Use one device for reliable and repeatable mass flow, volume flow, density, concentration and temperature measurement
- Get the best real-world Coriolis performance at operating pressures up to 15,374 psi (0-1,060 bar)
- Minimize maintenance and boost long-term reliability with no moving parts to wear or replace
- Maximize uptime using Smart Meter Verification to check system integrity without need to pull meter out of service
- Accommodate any installation requirement with available two-wire, direct-connect (no transmitter needed), stainless steel and 5700 transmitters
- Dramatically reduce operating expenses for chemical injection and hydrogen dispensers.
Micro Motion 2400S Compact, Integral-Mount Transmitter- Receive diagnostics for performance under entrained gas and batching from empty applications with MVD digital processing
- Gain real-time and in-process measurement integrity assurance with Smart Meter Verification
- Employ the best two-phase flow capability for batching, loading and entrained gas applications
- Eliminate the need to remove the transmitter cover with optical buttons on the display
- Rely on Class 1, Div. 2 (Zone 2 ) hazardous area approval (sensor and transmitter )