Ahwaz Electromechanical Technology

Focusing on Instrumentation: Competitive Pricing with Swift Delivery

MicroMotionR-SeriesCoriolisMeterConsistingofR050SSensorand1700Transmitter-AhwazAutomation|ProcessControls|AhwazMeasurementInstruments

ROSEMOUNT/Flow Measurement/Coriolis/

Micro Motion R-Series Coriolis Meter Consisting of R050S Sensor and 1700 Transmitter

Micro Motion R050S Coriolis Meter, 1/2 Inch (DN15), 316L Stainless Steel

Micro Motion 1700 Single Variable Field Mount Flow Transmitter

 

  • Product Details

Specifications

Micro Motion R050S Coriolis Meter, 1/2 Inch (DN15), 316L Stainless Steel
Mass flow accuracy (Liquid):
           ±0.50% of rate (standard)±0.40% of rate (optional)
Mass flow repeatability (Liquid):
           ±0.25% of rate (standard)±0.20% of rate (optional)
Volume flow accuracy (Liquid):
           ±0.50% of rate
Volume flow repeatability (Liquid):
            ±0.25% of rate
Mass flow accuracy (Gas):
            ±0.75% of rate
Mass flow repeatability (Gas):
            ±0.50% of rate
Density accuracy (Liquid):
            ±0.01 g/cm³ (10.0 kg/m³) (standard)±0.003 g/cm³ (3.0 kg/m³) (optional)
Temperature accuracy:
            ±1 °C ±0.5% of reading
Sensor maximum working pressure:
            1,450 psig (100 barg)
Meter approvals, calibrations, and certifications:
• CSA
• IECEx
• NEPSI
• ATEX
Micro Motion 1700 Single Variable Field Mount Flow Transmitter
Output variables
  • Mass flow
  • Volume flow
Local display
Standard user interface with 2-line LCD panel

  • Two optical switches for local operation
  • Glass or plastic lens options
Power
Self-switching AC/DC input, automatically recognizes supply voltage

  • 85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum
  • 18 to 100 VDC, 6 watts typical, 11 watts maximum
  • Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2, and Installation (Overvoltage) Category II, Pollution Degree 2
Input/output signals
  • One active 4–20 mA output
  • One active frequencty output
  • Frequency output can be configured as a discrete output
HART
  • Bell 202 signal is superimposed on the primary milliamp output
Mounting options
Field-mount

  • Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor
  • Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
Application types
  • Continuous process control
  • Two-phase flow/entrained gas
  • Meter verification
  • SIS Certified
Hazardous approvals
  • Class I, Div. 1
  • Class I, Div. 2
  • Zone 1
  • Zone 2

    Features

    Micro Motion R050S Coriolis Meter, 1/2 Inch (DN15), 316L Stainless Steel
    • Achieve high-performance basic liquid mass flow and volume flow measurement in a compact design
    • Increase flexibility with available 316L stainless steel construction that is compatible with most fluids
    • Cut costs with an integral transmitter that provides a flow-variable-only architecture
    • Choose from rugged transmitter options including: Class I, Division 1/Zone 1 housing with optional local-operator interface
    • Broad range of meter approvals and certifications, including; CSA (Class 1 Div 1 groups C and D, Class 1 Div 2 groups A, B, C and D), ATEX, IECEx, Ingress Protection 66/67, and NAMUR
    • Minimize maintenance and boost long-term reliability with no moving parts to wear or replace
    • Install virtually anywhere with compact design
    Micro Motion 1700 Single Variable Field Mount Flow Transmitter
    • Maximize flexibility with integral or remote mounting
    • Receive diagnostics for performance under entrained gas and batching from empty applications with MVD digital processing
    • Lower wiring costs and install easily and quickly
    • Eliminate the need for additional instruments with concentration and net flow measurement
    • Rely on custody-transfer approval and certification for SIL2 and SIL3
    • Gain real-time and in-process measurement integrity assurance with Smart Meter Verification
    • Gain access to additional diagnostics and process information without added wiring costs with WirelessHART
    • Simplify flow-meter access with rugged Class I, Division 1 / Zone 1 housing with an optional local operator interface