Ahwaz Electromechanical Technology

Focusing on Instrumentation: Competitive Pricing with Swift Delivery

MicroMotionR-SeriesCoriolisMeterConsistingofR200SSensorand2700Transmitter-AhwazAutomation|ProcessControls|AhwazMeasurementInstruments

ROSEMOUNT/Flow Measurement/Coriolis/

Micro Motion R-Series Coriolis Meter Consisting of R200S Sensor and 2700 Transmitter

Micro Motion R200S Coriolis Meter, 2 Inch (DN50), 316L Stainless Steel
Micro Motion 2700 Field And Integral-Mount Multivariable Flow And Density Transmitter

  • Product Details

Specifications

Micro Motion R200S Coriolis Meter, 2 Inch (DN50), 316L Stainless Steel
Mass flow accuracy (Liquid):
              ±0.50% of rate (standard)±0.40% of rate (optional)
Mass flow repeatability (Liquid):
              ±0.25% of rate (standard)±0.20% of rate (optional)
Volume flow accuracy (Liquid):
               ±0.50% of rate
Volume flow repeatability (Liquid):
                ±0.25% of rate
Mass flow accuracy (Gas):
                ±0.75% of rate
Mass flow repeatability (Gas):
               ±0.50% of rate
Density accuracy (Liquid):
              ±0.01 g/cm³ (10.0 kg/m³) (standard)±0.003 g/cm³ (3.0 kg/m³) (optional)
Temperature accuracy:
              ±1 °C ±0.5% of reading
Sensor maximum working pressure:
              1,450 psig (100 barg)
Meter approvals, calibrations, and certifications:
• CSA
• IECEx
• NEPSI
• ATEX
Micro Motion 2700 Field And Integral-Mount Multivariable Flow And Density Transmitter
Output variables:
              Mass & volume flow
Net product content / flow
Temperature
Density
Concentration
Local display:
              Standard user interface with 2-line LCD panel
Two optical switches for local operation:
Glass or plastic lens options
Power:
             Self-switching AC/DC input, automatically recognizes supply voltage
85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum
18 to 100 VDC, 6 watts typical, 11 watts maximum
Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2, and Installation (Overvoltage) Category II, Pollution Degree 2
Input/output signals:
    1. Not intrinsically safe
      Analog output option:

      • One active 4–20 mA output
      • One active frequencty output
        Frequency output can be configured as a discrete output

      Configurable I/O option:

      • One or two active 4-20 mA outputs
      • One or two active/passive frequency outputs
      • One or two active/passive discrete outputs
      • One discrete input
    2. Intrinsically safe
    1. Analog output option:

      • One passive 4-20 mA output
      • One passive frequency output
      • Frequency output can be configured as a discrete output
    1. Foundation fieldbus (Obsolete)

      • optionally non-incendive
      • One Foundation fieldbus H1 output
    PROFIBUS-PA (Obsolete)

    • One PROFIBUS-PA output
HART/WirelessHART:
            Bell 202 signal is superimposed on the primary milliamp output
            WirelessHART available via THUM adapter
HART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions
Mounting options:
       Field-mount

  • Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor
  • Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
Application types:
            Continuous process control
Custody transfer
Two-phase flow/entrained gas
Meter verification
SIS Certified
Hazardous approvals:
            Class I, Div. 1
Class I, Div. 2
Zone 1
Zone 2
HART/WirelessHART:
             Bell 202 signal is superimposed on the primary milliamp output
WirelessHART available via THUM adapter
HART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions
Mounting options:
           Field-mount
•Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor
•Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
Application types:
           Continuous process control
Custody transfer
Two-phase flow/entrained gas
Meter verification
SIS Certified
Hazardous approvals:
           Class I, Div. 1
Class I, Div. 2
Zone 1
Zone 2

Features

Micro Motion R200S Coriolis Meter, 2 Inch (DN50), 316L Stainless Steel
  • Achieve high-performance basic liquid mass flow and volume flow measurement in a compact design
  • Increase flexibility with available 316L stainless steel construction that is compatible with most fluids
  • Cut costs with an integral transmitter that provides a flow-variable-only architecture
  • Choose from rugged transmitter options including: Class I, Division 1/Zone 1 housing with optional local-operator interface
  • Broad range of meter approvals and certifications, including; CSA (Class 1 Div 1 groups C and D, Class 1 Div 2 groups A, B, C and D), ATEX, IECEx, Ingress Protection 66/67, and NAMUR
  • Minimize maintenance and boost long-term reliability with no moving parts to wear or replace
  • Install virtually anywhere with compact design
Micro Motion 2700 Field And Integral-Mount Multivariable Flow And Density Transmitter
  • Maximize flexibility with integral or remote mounting
  • Receive diagnostics for performance under entrained gas and batching from empty applications with MVD digital processing
  • Lower wiring costs and install easily and quickly
  • Eliminate the need for additional instruments with concentration and net flow measurement
  • Rely on custody-transfer approval and certification for SIL2 and SIL3
  • Gain real-time and in-process measurement integrity assurance with Smart Meter Verification
  • Gain access to additional diagnostics and process information without added wiring costs with WirelessHART
  • Simplify flow-meter access with rugged Class I, Division 1 / Zone 1 housing with an optional local operator interface

Prev: