Specifications
Micro Motion R200S Coriolis Meter, 2 Inch (DN50), 316L Stainless Steel
- Mass flow accuracy (Liquid):
- ±0.50% of rate (standard)±0.40% of rate (optional)
- Mass flow repeatability (Liquid):
- ±0.25% of rate (standard)±0.20% of rate (optional)
- Volume flow accuracy (Liquid):
- ±0.50% of rate
- Volume flow repeatability (Liquid):
- ±0.25% of rate
- Mass flow accuracy (Gas):
- ±0.75% of rate
- Mass flow repeatability (Gas):
- ±0.50% of rate
- Density accuracy (Liquid):
- ±0.01 g/cm³ (10.0 kg/m³) (standard)±0.003 g/cm³ (3.0 kg/m³) (optional)
- Temperature accuracy:
- ±1 °C ±0.5% of reading
- Sensor maximum working pressure:
- 1,450 psig (100 barg)
- Meter approvals, calibrations, and certifications:
- • CSA
• IECEx
• NEPSI
• ATEX
Micro Motion 2700 Field And Integral-Mount Multivariable Flow And Density Transmitter
- Output variables:
- Mass & volume flow
Net product content / flow
Temperature
Density
Concentration
- Local display:
- Standard user interface with 2-line LCD panel
Two optical switches for local operation:
Glass or plastic lens options
- Power:
- Self-switching AC/DC input, automatically recognizes supply voltage
85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum
18 to 100 VDC, 6 watts typical, 11 watts maximum
Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2, and Installation (Overvoltage) Category II, Pollution Degree 2
- Input/output signals:
- Not intrinsically safe
Analog output option:- One active 4–20 mA output
- One active frequencty output
Frequency output can be configured as a discrete output
Configurable I/O option:
- One or two active 4-20 mA outputs
- One or two active/passive frequency outputs
- One or two active/passive discrete outputs
- One discrete input
- Intrinsically safe
- Not intrinsically safe
- Analog output option:
- One passive 4-20 mA output
- One passive frequency output
- Frequency output can be configured as a discrete output
- Foundation fieldbus (Obsolete)
- optionally non-incendive
- One Foundation fieldbus H1 output
- PROFIBUS-PA (Obsolete)
- One PROFIBUS-PA output
- HART/WirelessHART:
- Bell 202 signal is superimposed on the primary milliamp output
WirelessHART available via THUM adapter
HART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions
- Mounting options:
- Field-mount
- Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor
- Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
- Application types:
- Continuous process control
Custody transfer
Two-phase flow/entrained gas
Meter verification
SIS Certified
- Hazardous approvals:
- Class I, Div. 1
Class I, Div. 2
Zone 1
Zone 2
- HART/WirelessHART:
- Bell 202 signal is superimposed on the primary milliamp output
WirelessHART available via THUM adapter
HART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions
- Mounting options:
- Field-mount
•Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor
•Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
- Application types:
- Continuous process control
Custody transfer
Two-phase flow/entrained gas
Meter verification
SIS Certified
- Hazardous approvals:
- Class I, Div. 1
Class I, Div. 2
Zone 1
Zone 2 Features
Micro Motion R200S Coriolis Meter, 2 Inch (DN50), 316L Stainless Steel- Achieve high-performance basic liquid mass flow and volume flow measurement in a compact design
- Increase flexibility with available 316L stainless steel construction that is compatible with most fluids
- Cut costs with an integral transmitter that provides a flow-variable-only architecture
- Choose from rugged transmitter options including: Class I, Division 1/Zone 1 housing with optional local-operator interface
- Broad range of meter approvals and certifications, including; CSA (Class 1 Div 1 groups C and D, Class 1 Div 2 groups A, B, C and D), ATEX, IECEx, Ingress Protection 66/67, and NAMUR
- Minimize maintenance and boost long-term reliability with no moving parts to wear or replace
- Install virtually anywhere with compact design
Micro Motion 2700 Field And Integral-Mount Multivariable Flow And Density Transmitter- Maximize flexibility with integral or remote mounting
- Receive diagnostics for performance under entrained gas and batching from empty applications with MVD digital processing
- Lower wiring costs and install easily and quickly
- Eliminate the need for additional instruments with concentration and net flow measurement
- Rely on custody-transfer approval and certification for SIL2 and SIL3
- Gain real-time and in-process measurement integrity assurance with Smart Meter Verification
- Gain access to additional diagnostics and process information without added wiring costs with WirelessHART
- Simplify flow-meter access with rugged Class I, Division 1 / Zone 1 housing with an optional local operator interface