Specifications
- Mass flow accuracy (Liquid)
- ±0.50% of rate (standard)±0.40% of rate (optional)
- Mass flow repeatability (Liquid)
- ±0.25% of rate (standard)±0.20% of rate (optional)
- Volume flow accuracy (Liquid)
- ±0.50% of rate
- Volume flow repeatability (Liquid)
- ±0.25% of rate
- Mass flow accuracy (Gas)
- ±0.75% of rate
- Mass flow repeatability (Gas)
- ±0.50% of rate
- Density accuracy (Liquid)
- ±0.01 g/cm³ (10.0 kg/m³) (standard)±0.003 g/cm³ (3.0 kg/m³) (optional)
- Temperature accuracy
- ±1 °C ±0.5% of reading
- Sensor maximum working pressure
- 1,450 psig (100 barg)
- Meter approvals, calibrations, and certifications
- • CSA
• IECEx
• NEPSI
• ATEX Features
- Achieve high-performance basic liquid mass flow and volume flow measurement in a compact design
- Increase flexibility with available 316L stainless steel construction that is compatible with most fluids
- Cut costs with an integral transmitter that provides a flow-variable-only architecture
- Choose from rugged transmitter options including: Class I, Division 1/Zone 1 housing with optional local-operator interface
- Broad range of meter approvals and certifications, including; CSA (Class 1 Div 1 groups C and D, Class 1 Div 2 groups A, B, C and D), ATEX, IECEx, Ingress Protection 66/67, and NAMUR
- Minimize maintenance and boost long-term reliability with no moving parts to wear or replace
- Install virtually anywhere with compact design