Specifications
Micro Motion T050T Straight Tube Coriolis Meter, 1/2 Inch (DN15), Titanium Grade 9, 32 Ra Finish
- Mass flow accuracy (Liquid):
- ±0.15% of rate
- Mass flow repeatability (Liquid):
- ±0.05% of rate
- Volume flow accuracy (Liquid):
- ±0.25% of rate
- Volume flow repeatability (Liquid):
- ±0.05% of rate
- Mass flow accuracy (Gas):
- ±0.50% of rate
- Mass flow repeatability (Gas):
- ±0.05% of rate
- Density accuracy (Liquid):
- ±0.002 g/cm3 (±2.0 kg/m3)
- Density repeatability (Liquid):
- ±0.0005 g/cm3 (±0.5 kg/m3)
- Temperature accuracy:
- ±1 °C ±0.5% of reading
- Sensor maximum working pressure:
- 1,450 psig (100 barg)
- Meter approvals, calibrations, and certifications:
- •UL
•CSA
•ATEX
•ASME
•3-A
•USDA
•EHEDG
Micro Motion 2400S Compact, Integral-Mount Transmitter
- Output variables:
- Mass & volume flow
Net product content / flow
Temperature
Density
Concentration
- Local display:
- Standard user interface with 2-line LCD panel
Two clips for HART/Bell 202 connections (requires removing transmitter housing cover)
Two membrane pushbuttons for local operation (requires removing transmitter housing cover)
Glass or plastic lens options
- Power:
- Self-switching AC/DC input, automatically recognizes supply voltage
85–265 VAC, 50/60 Hz, 4 watts typical, 7 watts maximum
18–100 VDC, 4 watts typical, 7 watts maximum
Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) and Installation (Overvoltage) Category II, Pollution Degree 2
- Input/output signals (analog output option):
- Channel A:
One active 4–20 mA output
Not intrinsically safeChannel B (configurable), one of:
One active or passive frequency output
One active or passive discrete output
One active or passive discrete input
- Input/output signals (PROFIBUS-DP option):
- Digital 2-way PROFIBUS-DP signal
- Input/output signals (DeviceNet option):
- Digital 2-way DeviceNet signal (Now Obsolete)
- HART:
- Bell 202 signal is superimposed on the primary milliamp output
HART communication is not available on PROFIBUS-DP and DeviceNet transmitter versions
- Mounting options:
- Field mount, integral with sensor
- Application types:
- Continuous process control
Two-phase flow/entrained gas
Meter verification
- Hazardous approvals:
- C1D2
Zone 2 Features
Micro Motion T050T Straight Tube Coriolis Meter, 1/2 Inch (DN15), Titanium Grade 9, 32 Ra Finish- Achieve direct, in-line measurement of mass flow, density, concentration and volume flow and temperature from one device
- Choose available titanium construction for compatibility with most fluids
- Meet virtually any connectivity needs with a wide range of transmitter offerings
- Use with hygienic applications with an improved 15 and 32 rA surface and EHEDG, certified, 3-A authorized and ASME BPE
- Broad range of meter approvals and certifications, including; CSA (Class 1 Div 1 groups C and D, Class 1 Div 2 groups A, B, C and D), ATEX, IECEx, Ingress Protection 66/67, and NAMUR
- Save time with a design that is easy to clean in place (CIP) and steam in place (SIP)
- Simplify installation with a highly robust design that doesn’t need straight runs or flow conditioning
Micro Motion 2400S Compact, Integral-Mount Transmitter- Receive diagnostics for performance under entrained gas and batching from empty applications with MVD digital processing
- Gain real-time and in-process measurement integrity assurance with Smart Meter Verification
- Employ the best two-phase flow capability for batching, loading and entrained gas applications
- Eliminate the need to remove the transmitter cover with optical buttons on the display
- Rely on Class 1, Div. 2 (Zone 2 ) hazardous area approval (sensor and transmitter )