Ahwaz Electromechanical Technology

Focusing on Instrumentation: Competitive Pricing with Swift Delivery

MicroMotionT-SeriesStraightTubeCoriolisMeterConsistingofT050TSensorand2400Transmitter-AhwazAutomation|ProcessControls|AhwazMeasurementInstruments

ROSEMOUNT/Flow Measurement/Coriolis/

Micro Motion T-Series Straight Tube Coriolis Meter Consisting of T050T Sensor and 2400 Transmitter

Micro Motion T050T Straight Tube Coriolis Meter, 1/2 Inch (DN15), Titanium Grade 9, 32 Ra Finish
Micro Motion 2400S Compact, Integral-Mount Transmitter

  • Product Details

Specifications

Micro Motion T050T Straight Tube Coriolis Meter, 1/2 Inch (DN15), Titanium Grade 9, 32 Ra Finish
Mass flow accuracy (Liquid):
            ±0.15% of rate
Mass flow repeatability (Liquid):
            ±0.05% of rate
Volume flow accuracy (Liquid):
            ±0.25% of rate
Volume flow repeatability (Liquid):
            ±0.05% of rate
Mass flow accuracy (Gas):
            ±0.50% of rate
Mass flow repeatability (Gas):
            ±0.05% of rate
Density accuracy (Liquid):
           ±0.002 g/cm3 (±2.0 kg/m3)
Density repeatability (Liquid):
           ±0.0005 g/cm3 (±0.5 kg/m3)
Temperature accuracy:
           ±1 °C ±0.5% of reading
Sensor maximum working pressure:
           1,450 psig (100 barg)
Meter approvals, calibrations, and certifications:
          •UL
•CSA
•ATEX
•ASME
•3-A
•USDA
•EHEDG
Micro Motion 2400S Compact, Integral-Mount Transmitter
Output variables:
            Mass & volume flow
Net product content / flow
Temperature
Density
Concentration
Local display:
           Standard user interface with 2-line LCD panel
Two clips for HART/Bell 202 connections (requires removing transmitter housing cover)
Two membrane pushbuttons for local operation (requires removing transmitter housing cover)
Glass or plastic lens options
Power:
          Self-switching AC/DC input, automatically recognizes supply voltage
85–265 VAC, 50/60 Hz, 4 watts typical, 7 watts maximum
18–100 VDC, 4 watts typical, 7 watts maximum
Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) and Installation (Overvoltage) Category II, Pollution Degree 2
Input/output signals (analog output option):
        Channel A:
One active 4–20 mA output
Not intrinsically safeChannel B (configurable), one of:
One active or passive frequency output
One active or passive discrete output
One active or passive discrete input
Input/output signals (PROFIBUS-DP option):
         Digital 2-way PROFIBUS-DP signal
Input/output signals (DeviceNet option):
         Digital 2-way DeviceNet signal (Now Obsolete)
HART:
         Bell 202 signal is superimposed on the primary milliamp output
HART communication is not available on PROFIBUS-DP and DeviceNet transmitter versions
Mounting options:
         Field mount, integral with sensor
Application types:
         Continuous process control
Two-phase flow/entrained gas
Meter verification
Hazardous approvals:
         C1D2
Zone 2

Features

Micro Motion T050T Straight Tube Coriolis Meter, 1/2 Inch (DN15), Titanium Grade 9, 32 Ra Finish
  • Achieve direct, in-line measurement of mass flow, density, concentration and volume flow and temperature from one device
  • Choose available titanium construction for compatibility with most fluids
  • Meet virtually any connectivity needs with a wide range of transmitter offerings
  • Use with hygienic applications with an improved 15 and 32 rA surface and EHEDG, certified, 3-A authorized and ASME BPE
  • Broad range of meter approvals and certifications, including; CSA (Class 1 Div 1 groups C and D, Class 1 Div 2 groups A, B, C and D), ATEX, IECEx, Ingress Protection 66/67, and NAMUR
  • Save time with a design that is easy to clean in place (CIP) and steam in place (SIP)
  • Simplify installation with a highly robust design that doesn’t need straight runs or flow conditioning
Micro Motion 2400S Compact, Integral-Mount Transmitter
  • Receive diagnostics for performance under entrained gas and batching from empty applications with MVD digital processing
  • Gain real-time and in-process measurement integrity assurance with Smart Meter Verification
  • Employ the best two-phase flow capability for batching, loading and entrained gas applications
  • Eliminate the need to remove the transmitter cover with optical buttons on the display
  • Rely on Class 1, Div. 2 (Zone 2 ) hazardous area approval (sensor and transmitter )

Prev:

Next:

Inquiry

    PersonalBusinessDistributor

    Get a Quote

    Error: Contact form not found.