Specifications
- Mass flow accuracy (Liquid)
- ±0.15% of rate
- Mass flow repeatability (Liquid)
- ±0.05% of rate
- Volume flow accuracy (Liquid)
- ±0.25% of rate
- Volume flow repeatability (Liquid)
- ±0.05% of rate
- Mass flow accuracy (Gas)
- ±0.50% of rate
- Mass flow repeatability (Gas)
- ±0.05% of rate
- Density accuracy (Liquid)
- ±0.002 g/cm3 (±2.0 kg/m3)
- Density repeatability (Liquid)
- ±0.0005 g/cm3 (±0.5 kg/m3)
- Temperature accuracy
- ±1 °C ±0.5% of reading
- Sensor maximum working pressure
- 1,450 psig (100 barg)
- Meter approvals, calibrations, and certifications
- •UL
•CSA
•ATEX
•ASME
•3-A
•USDA
•EHEDG Features
- Achieve direct, in-line measurement of mass flow, density, concentration and volume flow and temperature from one device
- Choose available titanium construction for compatibility with most fluids
- Meet virtually any connectivity needs with a wide range of transmitter offerings
- Use with hygienic applications with an improved 15 and 32 rA surface and EHEDG, certified, 3-A authorized and ASME BPE
- Broad range of meter approvals and certifications, including; CSA (Class 1 Div 1 groups C and D, Class 1 Div 2 groups A, B, C and D), ATEX, IECEx, Ingress Protection 66/67, and NAMUR
- Save time with a design that is easy to clean in place (CIP) and steam in place (SIP)
- Simplify installation with a highly robust design that doesn’t need straight runs or flow conditioning