Specifications
Rosemount 0085 Pipe Clamp Temperature Sensor
- Pipe Clamp Materials
- ASTM 304 SST (1.4301), Duplex F51 (1.4462), Carbon steel (1.0037)
- Lead Wires
- PTFE insulated, silver-coated copper wire
- Insulation Resistance
- 1,000 MΩ minimum insulation resistance when measured at 500 V dc at room temperature
- Calibration Options
- Class A Sensor from -50 to 300 °C (-58 to 572 °F)
- Certifications/Approvals
- Hazardous location, see full specs for complete list of certifications
Rosemount 248 Head Mount Temperature Transmitter
- Input
- Single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
- Output Signal
- 4-20 mA /HART protocol
- Housing
- DIN B head mount
- Diagnostics
- Basic diagnostics including open/short sensor diagnostics
- Calibration Options
- 5-point calibration
- Certifications/Approvals
- SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certifications
Features
Rosemount 0085 Pipe Clamp Temperature Sensor- Sensor covers wide range of temperatures -328 to 572 °F (-200 ° to 300 °C) to meet application demands
- Direct mounts to Rosemount 648 Wireless with Rosemount X-well Technology for accurate process temperature measurement
- Wide variety of clamp styles, sizes, and materials allows for installation anywhere and provides application flexibility
- Installation requires only two bolts (no welding required) for a straightforward connection
- Platinum RTD temperature sensors designed with silver or nickel tip for improved response time
- Withstands applications with high velocities, heavy liquids or particulates for durability and stability
- Non-intrusive design eliminates need for process penetration of fluids with toxic properties for added safety
- Spring-loaded sensor ensures best surface contact for enhanced performance
Rosemount 248 Head Mount Temperature Transmitter- Standard transmitter meets common single point temperature measurement application requirements
- Housing construction provides superior resistance to many process environments
- One-year stability rating reduces maintenance costs
- Open/short sensor diagnostics help detect issues in the sensor loop to ensure reliable performance
- Device dashboards provide easy interface for simplified device configuration and diagnostic troubleshooting
- Transmitter-sensor matching with Callendar-Van Dusen constants reduces total measurement error