Specifications
Rosemount 0085 Pipe Clamp Temperature Sensor
- Pipe Clamp Materials
- ASTM 304 SST (1.4301), Duplex F51 (1.4462), Carbon steel (1.0037)
- Lead Wires
- PTFE insulated, silver-coated copper wire
- Insulation Resistance
- 1,000 MΩ minimum insulation resistance when measured at 500 V dc at room temperature
- Calibration Options
- Class A Sensor from -50 to 300 °C (-58 to 572 °F)
- Certifications/Approvals
- Hazardous location, see full specs for complete list of certifications
Rosemount 848T Temperature Transmitter
- Input
- Eight independently configurable inputs, including 2- and 3- wire RTDs, thermocouples, mV, 2- and 3- wire ohm, and 4-20 mA signals
- Output Signal
- FOUNDATION Fieldbus protocol
- Housing
- Aluminum, or stainless steel junction box
- Diagnostics
- Measurement validation
- Certifications/Approvals
- Hazardous location, marine type, see full specs for complete list of certifications
Features
Rosemount 0085 Pipe Clamp Temperature Sensor- Sensor covers wide range of temperatures -328 to 572 °F (-200 ° to 300 °C) to meet application demands
- Direct mounts to Rosemount 648 Wireless with Rosemount X-well Technology for accurate process temperature measurement
- Wide variety of clamp styles, sizes, and materials allows for installation anywhere and provides application flexibility
- Installation requires only two bolts (no welding required) for a straightforward connection
- Platinum RTD temperature sensors designed with silver or nickel tip for improved response time
- Withstands applications with high velocities, heavy liquids or particulates for durability and stability
- Non-intrusive design eliminates need for process penetration of fluids with toxic properties for added safety
- Spring-loaded sensor ensures best surface contact for enhanced performance
Rosemount 848T Temperature Transmitter- Transmitter accepts up to eight temperature measurements per device for reduced process control costs
- Measurements can be taken in close proximity to each other for simplified installation and reduced wiring
- Receives independently configurable RTD, thermocouple, ohm and milliamp inputs for high density applications
- Integrates existing analog instrumentation into FOUNDATION Fieldbus environment for added digital functionality
- Bus-powered transmitter further reduces the amount of required wiring to install the device
- Measurement validation diagnostic detects data abnormalities and on-scale failures to avoid shutdowns
- Device dashboards display an easy interface for simplified device configuration and diagnostic troubleshooting