Ahwaz Electromechanical Technology

Focusing on Instrumentation: Competitive Pricing with Swift Delivery

214CRTDTemperatureSensor,248Transmitter-AhwazAutomation|ProcessControls|AhwazMeasurementInstruments

Temperature Transmitters/Temperature Measurement/ROSEMOUNT/

214C RTD Temperature Sensor, 248 Transmitter

Specifications Rosemount 214C RTD Temperature Sensor Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008 Lead Wires: 24 AWG wire, FEP insulated; color coded per IEC 60751 Time Constant / Response: 10.8 seconds maximum required to reach 50% sensor response when tested in flowing water according to IEC 60751:2008 Stability: ±0.15 °C (0.059 ) maximum ice-point resistance shift following 1,000 hours at maximum specified temperature when measured per methods defined in IEC 60751:2008 Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500 VDC at room temperature Calibration Options: IEC 751 Class A or B; Single point calibration; Calibration schedule…

  • Product Details

Specifications

Rosemount 214C RTD Temperature Sensor
Temperature Range:
For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008
Lead Wires:
24 AWG wire, FEP insulated; color coded per IEC 60751
Time Constant / Response:
10.8 seconds maximum required to reach 50% sensor response when tested in flowing water according to IEC 60751:2008
Stability:
±0.15 °C (0.059 ) maximum ice-point resistance shift following 1,000 hours at maximum specified temperature when measured per methods defined in IEC 60751:2008
Insulation Resistance:
1000 MΩ minimum insulation resistance when measured at 500 VDC at room temperature
Calibration Options:
IEC 751 Class A or B; Single point calibration; Calibration schedule or customer-specified calibration range, both with Callendar-Van Dusen constants
Rosemount 248 Head Mount Temperature Transmitter
Input:
Single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
Output Signal:
4-20 mA /HART protocol
Housing:
DIN B head mount
Diagnostics:
Basic diagnostics including open/short sensor diagnostics
Calibration Options:
5-point calibration
Certifications/Approvals:
SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certifications

Prev:

Next:

Inquiry

    PersonalBusinessDistributor

    Get a Quote

    Error: Contact form not found.