Specifications
Rosemount 214C RTD Temperature Sensor
- Temperature Range: For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008
- Lead Wires: 24 AWG wire, FEP insulated; color coded per IEC 60751
- Time Constant / Response: 10.8 seconds maximum required to reach 50% sensor response when tested in flowing water according to IEC 60751:2008
- Stability: ±0.15 °C (0.059 ) maximum ice-point resistance shift following 1,000 hours at maximum specified temperature when measured per methods defined in IEC 60751:2008
- Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500 VDC at room temperature
- Calibration Options: IEC 751 Class A or B; Single point calibration; Calibration schedule or customer-specified calibration range, both with Callendar-Van Dusen constants
Rosemount 848T Wireless Temperature Transmitter
- Input: Four independently configurable inputs, including 2-, 3- and 4-wire RTDs, thermocouples, 0-1000mV and 0-10V, 2-, 3- and 4-wire ohm, and 4-20 mA signals
- Output Signal: WirelessHART Protocol
- Housing: Field hardened aluminum enclosure
- Calibration Options: 5-point calibration
- Certifications/Approvals: Hazardous location, marine type, see full specs for complete list of certifications
- Update Rate: 4 sec. to 60 min., user selectable
- Power Module Life: Up to 10-year life, field replaceable (order separately)
- Antenna Type: External (standard and extended range)
Rosemount 114C Thermowell
- Thermowell Calculations: Wake frequency calculation (WFC) performed by certified engineers, order R21 for official report
- Design Modifiers: Root, bore and tip diameters can be customized for any application
- Certifications/Approvals: Material certification, NACE, CRN (see full specs for complete list of certifications)
- Product Tests: External pressure test, internal pressure test, dye penetration, X-ray, PMI (see full specs for complete list)
Features
Rosemount 214C RTD Temperature Sensor
- Single or dual element Pt-100 RTD with thin-film or wire-wound designs meets various application requirements
- Thin film sensor engineered to withstand high vibration industrial applications
- Wire-wound design for applications requiring high accuracy, dual-elements and/or are subjected to high temperatures
- Covers a wide range of temperatures from –321 to 1112°F (–196 to 600°C) for application flexibility
- Callendar-Van Dusen constants allow for transmitter-sensor matching and offer the highest level of accuracy
- Optional Class A accuracy ensures critical temperature measurement points meet tolerance and accuracy standards
- Adaptable design with a variety of enclosure and connection head options meet varying application demands
- Includes spring-loaded or compact spring-loaded mounting styles for adaptability
- North American approvals meet hazardous location requirements
Rosemount 848T Wireless Temperature Transmitter
- WirelessHART technology is secure, cost-effective and delivers >99% data reliability
- Best price per point solution accepts four configurable inputs (RTD, thermocouple, ohm, millivolt and 4 to 20 mA signals)
- Field-hardened enclosure allows for installation close to any process, even in harsh environments and hazardous areas
- Extended range antenna offers wireless communication for long distance installations
- Designed with up to eight configurable alerts for advanced measurement monitoring
- Device dashboards display an easy interface for simplified device configuration and diagnostic troubleshooting
- SmartPower module provides up to 10-year maintenance-free operation and field replacement without transmitter removal
- Easy installation enables quick instrumentation of measurement points without the cost of wiring
Rosemount 114C Thermowell
- Threaded, flanged, Van Stone and welded mounting styles with stem profile options allow for application flexibility
- Wide selection of thermowell materials, from stainless steel to exotic materials, meets varying process specifications
- Option of Wake Frequency Calculation report ensures thermowell design is compatible with process conditions
- Flexible design modifiers for root, bore and tip thickness allow customization for special application requirements
- Van Stone style permits differing flange material from the stem for cost-efficiency
- Thermowell options, including NACE, material certification and PMI, ensure material traceability or compatibility
- Special testing options to meet process requirements including external hydrostatic pressure test, dye penetration test and more