Ahwaz Electromechanical Technology

Focusing on Instrumentation: Competitive Pricing with Swift Delivery

Rosemount214CRTDTemperatureSensorand3144PTemperatureTransmitter-AhwazAutomation|ProcessControls|AhwazMeasurementInstruments

Temperature Transmitters/Temperature Sensors/Temperature Measurement/ROSEMOUNT/

Rosemount 214C RTD Temperature Sensor and 3144P Temperature Transmitter

Specifications Rosemount 214C RTD Temperature Sensor Temperature Range:For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008 Lead Wires:24 AWG wire, FEP insulated; color coded per IEC 60751 Time Constant / Response:10.8 seconds maximum required to reach 50% sensor response when tested in flowing water according to IEC 60751:2008 Stability:±0.15 °C (0.059 ) maximum ice-point resistance shift following 1,000 hours at maximum specified temperature when measured per methods defined in IEC 60751:2008 Insulation Resistance:1000 MΩ minimum insulation resistance when measured at 500 VDC at room temperature Calibration Options:IEC 751 Class A or B; Single point calibration; Calibration schedule or customer-specified calibration range, both with…

  • Product Details

Specifications

Rosemount 214C RTD Temperature Sensor
Temperature Range:For wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008
Lead Wires:24 AWG wire, FEP insulated; color coded per IEC 60751
Time Constant / Response:10.8 seconds maximum required to reach 50% sensor response when tested in flowing water according to IEC 60751:2008
Stability:±0.15 °C (0.059 ) maximum ice-point resistance shift following 1,000 hours at maximum specified temperature when measured per methods defined in IEC 60751:2008
Insulation Resistance:1000 MΩ minimum insulation resistance when measured at 500 VDC at room temperature
Calibration Options:IEC 751 Class A or B; Single point calibration; Calibration schedule or customer-specified calibration range, both with Callendar-Van Dusen constants
Rosemount 3144P Temperature Transmitter
Input:Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
Output Signal:4-20 mA /HART protocol, FOUNDATION Fieldbus protocol
Housing:Dual-compartment field mount
Display/Interface:Large LCD display with percent range graph and buttons/switches
Diagnostics:Basic diagnostics, Hot Backup capability, sensor drift alert, thermocouple degradation, min/max tracking
Calibration Options:Transmitter-sensor matching (Callendar-Van Dusen constants), custom trim
Certifications/Approvals:SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certifications

Features

Rosemount 214C RTD Temperature Sensor
  • Single or dual element Pt-100 RTD with thin-film or wire-wound designs meets various application requirements
  • Thin film sensor engineered to withstand high vibration industrial applications
  • Wire-wound design for applications requiring high accuracy, dual-elements and/or are subjected to high temperatures
  • Covers a wide range of temperatures from –321 to 1112°F (–196 to 600°C) for application flexibility
  • Callendar-Van Dusen constants allow for transmitter-sensor matching and offer the highest level of accuracy
  • Optional Class A accuracy ensures critical temperature measurement points meet tolerance and accuracy standards
  • Adaptable design with a variety of enclosure and connection head options meet varying application demands
  • Includes spring-loaded or compact spring-loaded mounting styles for adaptability
  • North American approvals meet hazardous location requirements
Rosemount 3144P Temperature Transmitter
  • Industry-leading accuracy and reliability for best performance in critical control and safety applications
  • Transmitter-sensor matching improves measurement accuracy up to 75%
  • 5-year long-term stability extends calibration intervals to reduce trips to the field
  • Rosemount X-well Technology measures temperature without a process penetration for reduced design, installation and maintenance costs
  • Dual compartment housing provides superior protection in harsh environments
  • Hot Backup capability and sensor drift alert utilizing dual sensors ensure measurement integrity
  • Thermocouple degradation diagnostic monitors thermocouple health to detect degradation before failure
  • Minimum and maximum temperature tracking allows monitoring of temperature extremes for easy troubleshooting
  • Transmitter supports multiple protocols for integration in many host environments across many industries
  • Device dashboards provide easy interface for simplified device configuration and diagnostic troubleshooting

Prev:

Next:

Inquiry

    PersonalBusinessDistributor

    Get a Quote

    Error: Contact form not found.