Ahwaz Electromechanical Technology

Focusing on Instrumentation: Competitive Pricing with Swift Delivery

Rosemount214CThermocoupleSensor,644Transmitterand114CThermowell-AhwazAutomation|ProcessControls|AhwazMeasurementInstruments

Temperature Transmitters/Temperature Sensors/Temperature Measurement/ROSEMOUNT/

Rosemount 214C Thermocouple Sensor, 644 Transmitter and 114C Thermowell

Specifications Rosemount 214C Thermocouple Temperature Sensor Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of certifications Lead Wires: 24 AWG wire, FEP insulated. Color coded per IEC 60584 or ASTM E230. Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals:Hazardous location, see full specs for complete list of certifications Rosemount 644 Temperature Transmitter Input: Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms) Output Signal: 4-20 mA /HART protocol, FOUNDATION fieldbus protocol, PROFIBUS PA protocol Housing: Field mount, DIN A head mount or rail mount Display/Interface: LCD Display, LCD Display with Local Operator Interface (LOI),…

  • Product Details

Specifications

Rosemount 214C Thermocouple Temperature Sensor
Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature
Certifications/Approvals: Hazardous location, see full specs for complete list of certifications
Lead Wires: 24 AWG wire, FEP insulated. Color coded per IEC 60584 or ASTM E230.
Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature
Certifications/Approvals:Hazardous location, see full specs for complete list of certifications
Rosemount 644 Temperature Transmitter
Input: Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
Output Signal: 4-20 mA /HART protocol, FOUNDATION fieldbus protocol, PROFIBUS PA protocol
Housing: Field mount, DIN A head mount or rail mount
Display/Interface: LCD Display, LCD Display with Local Operator Interface (LOI), or LED
Diagnostics: Basic diagnostics, Hot Backup capability, sensor drift alert, thermocouple degradation, min/max tracking
Calibration Options:Transmitter-sensor matching (Callendar-Van Dusen constants), 5-point calibration
Certifications/Approvals:SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certifications
Rosemount 114C Thermowell
Thermowell Calculations: Wake frequency calculation (WFC) performed by certified engineers, order R21 for official report
Design Modifiers:Root, bore and tip diameters can be customized for any application
Certifications/Approvals:Material certification, NACE, CRN (see full specs for complete list of certifications)
Product Tests:External pressure test, internal pressure test, dye penetration, X-ray, PMI (see full specs for complete list)

Features

Rosemount 214C Thermocouple Temperature Sensor
  • Sensor types include J, K and T thermocouples for application flexibility
  • Meets ASTM and IEC standards for thermocouple accuracy tolerance, providing reliable performance
  • Covers a wide range of temperatures from -196 to 1200 °C (-321 to 2192 °F) for durability in varying process environments
  • Withstands high vibration to offer resilience in tough process conditions
  • Available in single or dual configurations with grounded or ungrounded junctions for process compatibility
  • All sensor styles and lengths are available in ¼-in. diameter mineral-insulated (MI) cable to meet industry standards
  • Adjustable or fixed compression fittings and spring-loaded or welded adapters meet specific mounting requirements
  • Enclosure and connection head options allow for process adaptability
  • Global hazardous location approvals to meet project requirements
Rosemount 644 Temperature Transmitter
  • Extremely versatile temperature transmitter available in HART, FOUNDATION Fieldbus or PROFIBUS protocols
  • Diverse mounting configurations including head, field or rail mount with many enclosure options
  • LOI option eliminates the need for special configuration tools (i.e. field communicator) for ease-of-use
  • Transmitter-sensor matching with Callendar-Van Dusen constants reduces total measurement error
  • Hot Backup capability and sensor drift alert with dual sensors ensure measurement integrity
  • Thermocouple degradation diagnostic monitors thermocouple health to detect degradation before failure
  • Minimum and maximum temperature tracking observes temperature extremes for easy troubleshooting
  • Device dashboards provide easy interface for simplified device configuration and diagnostic troubleshooting
Rosemount 114C Thermowell
  • Threaded, flanged, Van Stone and welded mounting styles with stem profile options allow for application flexibility
  • Wide selection of thermowell materials, from stainless steel to exotic materials, meets varying process specifications
  • Option of Wake Frequency Calculation report ensures thermowell design is compatible with process conditions
  • Flexible design modifiers for root, bore and tip thickness allow customization for special application requirements
  • Van Stone style permits differing flange material from the stem for cost-efficiency
  • Thermowell options, including NACE, material certification and PMI, ensure material traceability or compatibility
  • Special testing options to meet process requirements including external hydrostatic pressure test, dye penetration test and more

Prev:

Next:

Inquiry

    PersonalBusinessDistributor

    Get a Quote

    Error: Contact form not found.