Ahwaz Electromechanical Technology

Focusing on Instrumentation: Competitive Pricing with Swift Delivery

214CThermocoupleSensor-AhwazAutomation|ProcessControls|AhwazMeasurementInstruments

Temperature Sensors/Temperature Measurement/ROSEMOUNT/

214C Thermocouple Sensor

Specifications Rosemount 214C Thermocouple Temperature Sensor Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of certifications Lead Wires: 24 AWG wire, FEP insulated. Color coded per IEC 60584 or ASTM E230. Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature Certifications/Approvals: Hazardous location, see full specs for complete list of certifications Rosemount 848T Temperature Transmitter Input: Eight independently configurable inputs, including 2- and 3- wire RTDs, thermocouples, mV, 2- and 3- wire ohm, and 4-20 mA signals Output Signal: FOUNDATION Fieldbus protocol Housing: Aluminum, or stainless steel junction box Diagnostics: Measurement validation Certifications/Approvals: Hazardous location, marine type, see full specs…

  • Product Details

Specifications

Rosemount 214C Thermocouple Temperature Sensor
Insulation Resistance:
1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature
Certifications/Approvals:
Hazardous location, see full specs for complete list of certifications
Lead Wires:
24 AWG wire, FEP insulated. Color coded per IEC 60584 or ASTM E230.
Insulation Resistance:
1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature
Certifications/Approvals:
Hazardous location, see full specs for complete list of certifications
Rosemount 848T Temperature Transmitter
Input:
Eight independently configurable inputs, including 2- and 3- wire RTDs, thermocouples, mV, 2- and 3- wire ohm, and 4-20 mA signals
Output Signal:
FOUNDATION Fieldbus protocol
Housing:
Aluminum, or stainless steel junction box
Diagnostics:
Measurement validation
Certifications/Approvals:
Hazardous location, marine type, see full specs for complete list of certifications
Rosemount 114C Thermowell
Thermowell Calculations:
Wake frequency calculation (WFC) performed by certified engineers, order R21 for official report
Design Modifiers:
Root, bore and tip diameters can be customized for any application
Certifications/Approvals:
Material certification, NACE, CRN (see full specs for complete list of certifications)
Product Tests:
External pressure test, internal pressure test, dye penetration, X-ray, PMI (see full specs for complete list)

Features

Rosemount 214C Thermocouple Temperature Sensor
  • Sensor types include J, K and T thermocouples for application flexibility
  • Meets ASTM and IEC standards for thermocouple accuracy tolerance, providing reliable performance
  • Covers a wide range of temperatures from -196 to 1200 °C (-321 to 2192 °F) for durability in varying process environments
  • Withstands high vibration to offer resilience in tough process conditions
  • Available in single or dual configurations with grounded or ungrounded junctions for process compatibility
  • All sensor styles and lengths are available in ¼-in. diameter mineral-insulated (MI) cable to meet industry standards
  • Adjustable or fixed compression fittings and spring-loaded or welded adapters meet specific mounting requirements
  • Enclosure and connection head options allow for process adaptability
  • Global hazardous location approvals to meet project requirements
Rosemount 848T Temperature Transmitter
  • Transmitter accepts up to eight temperature measurements per device for reduced process control costs
  • Measurements can be taken in close proximity to each other for simplified installation and reduced wiring
  • Receives independently configurable RTD, thermocouple, ohm and milliamp inputs for high density applications
  • Integrates existing analog instrumentation into FOUNDATION Fieldbus environment for added digital functionality
  • Bus-powered transmitter further reduces the amount of required wiring to install the device
  • Measurement validation diagnostic detects data abnormalities and on-scale failures to avoid shutdowns
  • Device dashboards display an easy interface for simplified device configuration and diagnostic troubleshooting
Rosemount 114C Thermowell
  • Threaded, flanged, Van Stone and welded mounting styles with stem profile options allow for application flexibility
  • Wide selection of thermowell materials, from stainless steel to exotic materials, meets varying process specifications
  • Option of Wake Frequency Calculation report ensures thermowell design is compatible with process conditions
  • Flexible design modifiers for root, bore and tip thickness allow customization for special application requirements
  • Van Stone style permits differing flange material from the stem for cost-efficiency
  • Thermowell options, including NACE, material certification and PMI, ensure material traceability or compatibility
  • Special testing options to meet process requirements including external hydrostatic pressure test, dye penetration test and more

Prev:

Next:

Inquiry

    PersonalBusinessDistributor

    Get a Quote

    Error: Contact form not found.