Specifications
- Accuracy: Up to ±0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, ±0.25% over 40:1 flow turndown.
- Diagnostic: In Situ Meter Verification, Grounding & Wiring Fault Detection, High Process Noise Detection, Tunable Empty Pipe Detection, Transmitter Fault Detection, Sensor Fault Detection
- Compatibility: All Rosemount manufactured Sensors: 8705, 8711, 8721, 8707
Universal capabilities allow E-Series transmitters to be compatible with AC and DC powered sensors from other manufacturers.
- Power Supply: 90-250 VAC, 50-60 Hz or 12-42 VDC.
- Power consumption:
- 15 W maximum – DC
40 VA maximum – AC
- Enclosure Rating
- 8712E: Type 4x, IP66
Features
- Intuitive Local Operator Interface with dedicated keys for ease of use
- Maximize uptime with Smart Meter Verification which monitors meter health and performance without stopping the process
- Optimize control in noisy applications with High Process Noise diagnostic and Selectable Coil Drive Frequency options
- Tunable Empty Pipe diagnostic minimizes issues and false readings when the pipe is empty
- Quickly verify installation integrity with Ground and Wiring Fault Detection diagnostic
- Universal transmitter capabilities enable reduced inventory and consistent interface for any magnetic flow meter sensor