Ahwaz Electromechanical Technology

Focusing on Instrumentation: Competitive Pricing with Swift Delivery

Rosemount9295

Flow Measurement/Differential Pressure Flow Meters and Transmitters/

Rosemount 9295 Process Flow Meter

The Rosemount   9295 Process Flow Meter offers exceptional performance in a complete integrated package. Engineered for ease-of-use, the 9295 incorporates proven Conditioning Orifice Technology to eliminate straight run requirements while the roddable impulse lines allow blockages to be removed without process shutdown. In addition, optional temperature measurement reduces installation cost and allows for fully compensated flow measurement. Specifications   Line Size 2 to 6 in (50 to 150 mm) Discharge Coefficient Uncertainty Calibrated: ±0.3 to 0.5%; Standard: ±0.75 to 1.5% Flow Turndown 10:1 or better Max. Operating Pressure ASME/ANSI B16.5 900# Process Temperature Range -20 to 850 °F (-29 to 454°C) Process Media Liquid, Gas, Steam Process Wetted Material 316 SST, Carbon Steel Warranty 5-year limited warranty Features Conditioning Orifice…

  • Product Details

The Rosemount   9295 Process Flow Meter offers exceptional performance in a complete integrated package. Engineered for ease-of-use, the 9295 incorporates proven Conditioning Orifice Technology to eliminate straight run requirements while the roddable impulse lines allow blockages to be removed without process shutdown. In addition, optional temperature measurement reduces installation cost and allows for fully compensated flow measurement.

Specifications

 

Line Size2 to 6 in (50 to 150 mm)
Discharge Coefficient UncertaintyCalibrated: ±0.3 to 0.5%; Standard: ±0.75 to 1.5%
Flow Turndown10:1 or better
Max. Operating PressureASME/ANSI B16.5 900#
Process Temperature Range-20 to 850 °F (-29 to 454°C)
Process MediaLiquid, Gas, Steam
Process Wetted Material316 SST, Carbon Steel
Warranty5-year limited warranty

Features

  • Conditioning Orifice Technology eliminates the need for straight pipe run which allows installation at grade level or in difficult piping configurations
  • Complete solution arrives assembled, configured and leak-checked, reducing on-site installation time and cost
  • Roddable design allows removal of impulse line plugging without the need for process shutdown
  • All-welded design eliminates potential leak points
  • Integral temperature sensor allows for a fully compensated flow measurement without the need for additional pipe penetrations or wake frequency calculations
  • Single piece machined body design without welds in the flow stream eliminates concerns with primary element breakage
  • Simplify SIS compliance with available redundant transmitter options
  • The simplicity and reliability of a DP Flow measurement without the hassle associated with a traditional installation

Prev:

Next:

Inquiry

    PersonalBusinessDistributor

    Get a Quote

    Error: Contact form not found.