Ideal for allocation and check metering, the fully-redundant Rosemount JuniorSonic 3412 Two-Path Gas Ultrasonic Flow Meter combines a dual-bounce path design with powerful 3410 Series Electronics to ensure a superior non-fiscal measurement solution. This cost-effective meter is wet gas tolerant and features rugged Rosemount T-21 Transducers that are engineered for wet, rich and/or dirty gas applications for reliable, long-term performance. Innovative MeterLink Software ensures operators have easy access to the diagnostics generated by the meter for real-time detection of flow disturbances.
Specifications
Line Sizes | DN100 to DN900 (4-in to 36-in) |
Fluid Type | Gas |
Accuracy | ±0.2% of reading with calibration (±1.5% of actual flow volume without calibration) |
Repeatability | ±0.1% of reading for 5 to 100 ft/s (1.5 to 30.5 m/s) |
Velocity | Rated up to 100 ft/s (30 m/s) with over-range performance exceeding 125 fps (38 m/s) on some sizes |
Operating Temperature Range | T-21 Transducers: -20°C to +100°C (-4°F to +212°F) |
T-41 Transducers: -50°C to +100°C (-58°F to +212°F) | |
Electronics: -40°C to +60°C (-40°F to +140°F) | |
Operating Pressure Range | T-21 Tranducers: 1034 to 27,579 kPa (150 to 4000 psig) |
T-41 Transducers: 1034 to 27,579 kPa (150 to 4000 psig) | |
Materials | Carbon steel and stainless steel |
Features
- Virtually eliminate incremental pressure drop and reduce energy costs with the meter’s full-bore design
- Improve maintenance practices and lower costs with no internal moving parts
- Detect flow disturbances in real time with ultra-fast Rosemount 3410 Series Electronics to minimize uncertainty
- Monitor flow analysis and receive an intuitive view of meter health with integrated MeterLink Software
- Enhance performance in harsh conditions long term with rugged Rosemount T-21 Transducers
Field-replaceable transformer module simplifies maintenance and maximizes uptime - Reduce manual errors with automatic calculations of AGA 8 Compressibility and AGA 10 Speed of Sound
- Increase I/O with new Type 4 CPU Module with up to six frequency or digital outputs