Preferred worldwide for fiscal measurement, the next-generation Rosemount SeniorSonic 3414 Four-Path Ultrasonic Flow Meter retains the field-proven, British Gas-chordal design while significantly increasing sampling speed with ultra-fast Rosemount 3410 Series Electronics. This powerful, high-performance meter minimizes measurement uncertainty by enabling rapid detection of changing flow dynamics such as blockages upstream of the meter, abnormal flow profiles and liquid hydrocarbons. MeterLink Software displays a wealth of predictive diagnostics generated by the meter, providing expert flow analysis, flow disturbance alerts and suggested corrective actions, to expedite detection before measurement is impacted.
Specifications
Line Sizes | DN100 to DN1050 (4-in to 42-in) |
DN100 to DN150 (4-in to 6-in) are 45° dual X orientation | |
DN200 (8-in) and larger are British Gas (BG) orientation | |
Fluid Type | Gas |
Accuracy | ±0.1% of reading relative over entire flow calibration range |
Repeatability | ±0.05% of reading for 5 to 100 ft/s (1.5 to 30.5 m/s) |
Velocity | Rated up to 100 ft/s (30 m/s) with over-range performance exceeding 125 ft/s (38 m/s) on some sizes |
Operating Temperature Range | T-21 Transducers: -20°C to +100°C (-4°F to +212°F) |
T-22 Transducers: -50°C to +100°C (-58°F to +212°F) | |
T-200 Transducers (up to 12” line size): –50°C to 125°C (–58°F to +257°F) | |
Operating Pressure Range | T-21/T-22 Transducers: 689 to 27,579 kPag (100 to 4,000 psig) |
T-21/T-22 Transducers: 345 kPag (50 psig) minimum operating pressure available with reduced Qmax | |
T-22 Transducers: 0 to 689 kPag (0 to 100 psig) isolated transducer mount | |
T-200 Transducer: 15 to 3,750 psig (1.03 to 258.55 bar) | |
Materials | Carbon steel and stainless steel |
Features
- Speed issue resolution with 3D view of the flow profile that indicates swirl, crossflow, asymmetry and turbulence
- Reduce manual errors with automatic calculations of AGA 8 Compressibility and AGA 10 Speed of Sound
- Reduce measurement uncertainty with process alerts for wall buildup, liquids, blockage and deviating gas quality
- Increase I/O with new Type 4 CPU Module with up to six frequency or digital outputs
- T-200 Transducers are safely extractable under pressure without special tools
- Increase I/O with new Type 4 CPU Module with up to six frequency or digital outputs
- Significantly reduce time previous spent on data analysis and troubleshooting with the new Smart Meter Verification Basic feature now included in the latest 3410 Electronics firmware update